| # SPDX-License-Identifier: GPL-2.0 | |
| config ARCH_VERSATILE | |
| bool "ARM Ltd. Versatile family" | |
| depends on ARCH_MULTI_V5 | |
| depends on CPU_LITTLE_ENDIAN | |
| select ARM_AMBA | |
| select ARM_TIMER_SP804 | |
| select ARM_VIC | |
| select CLKSRC_VERSATILE | |
| select CPU_ARM926T | |
| select CLK_ICST | |
| select MFD_SYSCON | |
| select PLAT_VERSATILE | |
| select POWER_RESET | |
| select POWER_RESET_VERSATILE | |
| select VERSATILE_FPGA_IRQ | |
| help | |
| This enables support for ARM Ltd Versatile board. | |
| menuconfig ARCH_INTEGRATOR | |
| bool "ARM Ltd. Integrator family" | |
| depends on ARCH_MULTI_V4T || ARCH_MULTI_V5 || ARCH_MULTI_V6 | |
| depends on CPU_LITTLE_ENDIAN || ARCH_MULTI_V6 | |
| select ARM_AMBA | |
| select CMA | |
| select DMA_CMA | |
| select HAVE_TCM | |
| select CLK_ICST | |
| select MFD_SYSCON | |
| select PLAT_VERSATILE | |
| select POWER_RESET | |
| select POWER_RESET_VERSATILE | |
| select POWER_SUPPLY | |
| select SOC_INTEGRATOR_CM | |
| select VERSATILE_FPGA_IRQ | |
| help | |
| Support for ARM's Integrator platform. | |
| if ARCH_INTEGRATOR | |
| config ARCH_INTEGRATOR_AP | |
| bool "Support Integrator/AP and Integrator/PP2 platforms" | |
| select INTEGRATOR_AP_TIMER | |
| select SERIAL_AMBA_PL010 if TTY | |
| select SERIAL_AMBA_PL010_CONSOLE if TTY | |
| select SOC_BUS | |
| help | |
| Include support for the ARM(R) Integrator/AP and | |
| Integrator/PP2 platforms. | |
| config INTEGRATOR_IMPD1 | |
| bool "Include support for Integrator/IM-PD1" | |
| depends on ARCH_INTEGRATOR_AP | |
| select ARM_VIC | |
| select GPIO_PL061 | |
| select GPIOLIB | |
| select REGULATOR | |
| select REGULATOR_FIXED_VOLTAGE | |
| help | |
| The IM-PD1 is an add-on logic module for the Integrator which | |
| allows ARM(R) Ltd PrimeCells to be developed and evaluated. | |
| The IM-PD1 can be found on the Integrator/PP2 platform. | |
| config INTEGRATOR_CM720T | |
| bool "Integrator/CM720T core module" | |
| depends on ARCH_INTEGRATOR_AP | |
| depends on ARCH_MULTI_V4T | |
| select CPU_ARM720T | |
| config INTEGRATOR_CM920T | |
| bool "Integrator/CM920T core module" | |
| depends on ARCH_INTEGRATOR_AP | |
| depends on ARCH_MULTI_V4T | |
| select CPU_ARM920T | |
| config INTEGRATOR_CM922T_XA10 | |
| bool "Integrator/CM922T-XA10 core module" | |
| depends on ARCH_MULTI_V4T | |
| depends on ARCH_INTEGRATOR_AP | |
| select CPU_ARM922T | |
| config INTEGRATOR_CM926EJS | |
| bool "Integrator/CM926EJ-S core module" | |
| depends on ARCH_INTEGRATOR_AP | |
| depends on ARCH_MULTI_V5 | |
| select CPU_ARM926T | |
| config INTEGRATOR_CM10200E_REV0 | |
| bool "Integrator/CM10200E rev.0 core module" | |
| depends on ARCH_INTEGRATOR_AP && n | |
| depends on ARCH_MULTI_V5 | |
| select CPU_ARM1020 | |
| config INTEGRATOR_CM10200E | |
| bool "Integrator/CM10200E core module" | |
| depends on ARCH_INTEGRATOR_AP && n | |
| depends on ARCH_MULTI_V5 | |
| select CPU_ARM1020E | |
| config INTEGRATOR_CM10220E | |
| bool "Integrator/CM10220E core module" | |
| depends on ARCH_INTEGRATOR_AP | |
| depends on ARCH_MULTI_V5 | |
| select CPU_ARM1022 | |
| config INTEGRATOR_CM1026EJS | |
| bool "Integrator/CM1026EJ-S core module" | |
| depends on ARCH_INTEGRATOR_AP | |
| depends on ARCH_MULTI_V5 | |
| select CPU_ARM1026 | |
| config INTEGRATOR_CM1136JFS | |
| bool "Integrator/CM1136JF-S core module" | |
| depends on ARCH_INTEGRATOR_AP | |
| depends on ARCH_MULTI_V6 | |
| select CPU_V6 | |
| config ARCH_INTEGRATOR_CP | |
| bool "Support Integrator/CP platform" | |
| depends on ARCH_MULTI_V5 || ARCH_MULTI_V6 | |
| select ARM_TIMER_SP804 | |
| select SERIAL_AMBA_PL011 if TTY | |
| select SERIAL_AMBA_PL011_CONSOLE if TTY | |
| select SOC_BUS | |
| help | |
| Include support for the ARM(R) Integrator CP platform. | |
| config INTEGRATOR_CT926 | |
| bool "Integrator/CT926 (ARM926EJ-S) core tile" | |
| depends on ARCH_INTEGRATOR_CP | |
| depends on ARCH_MULTI_V5 | |
| select CPU_ARM926T | |
| config INTEGRATOR_CTB36 | |
| bool "Integrator/CTB36 (ARM1136JF-S) core tile" | |
| depends on ARCH_INTEGRATOR_CP | |
| depends on ARCH_MULTI_V6 | |
| select CPU_V6 | |
| config ARCH_CINTEGRATOR | |
| depends on ARCH_INTEGRATOR_CP | |
| def_bool y | |
| endif | |
| menuconfig ARCH_REALVIEW | |
| bool "ARM Ltd. RealView family" | |
| depends on (CPU_LITTLE_ENDIAN && ARCH_MULTI_V5) || ARCH_MULTI_V6 || ARCH_MULTI_V7 | |
| select ARM_AMBA | |
| select ARM_GIC | |
| select ARM_TIMER_SP804 | |
| select CLK_SP810 | |
| select GPIO_PL061 if GPIOLIB | |
| select HAVE_ARM_SCU if SMP | |
| select HAVE_ARM_TWD if SMP | |
| select HAVE_PATA_PLATFORM | |
| select HAVE_TCM | |
| select CLK_ICST | |
| select MACH_REALVIEW_EB if ARCH_MULTI_V5 | |
| select MFD_SYSCON | |
| select PLAT_VERSATILE | |
| select POWER_RESET | |
| select POWER_RESET_VERSATILE | |
| select POWER_SUPPLY | |
| select SOC_REALVIEW | |
| help | |
| This enables support for ARM Ltd RealView boards. | |
| if ARCH_REALVIEW | |
| config MACH_REALVIEW_EB | |
| bool "Support RealView(R) Emulation Baseboard" | |
| select ARM_GIC | |
| select CPU_ARM926T if ARCH_MULTI_V5 | |
| help | |
| Include support for the ARM(R) RealView(R) Emulation Baseboard | |
| platform. On an ARMv5 kernel, this will include support for | |
| the ARM926EJ-S core tile, while on an ARMv6/v7 kernel, at least | |
| one of the ARM1136, ARM1176, ARM11MPCore or Cortex-A9MPCore | |
| core tile options should be enabled. | |
| config REALVIEW_EB_ARM1136 | |
| bool "Support ARM1136J(F)-S Tile" | |
| depends on MACH_REALVIEW_EB && ARCH_MULTI_V6 | |
| select CPU_V6 | |
| help | |
| Enable support for the ARM1136 tile fitted to the | |
| Realview(R) Emulation Baseboard platform. | |
| config REALVIEW_EB_ARM1176 | |
| bool "Support ARM1176JZ(F)-S Tile" | |
| depends on MACH_REALVIEW_EB && ARCH_MULTI_V6 | |
| help | |
| Enable support for the ARM1176 tile fitted to the | |
| Realview(R) Emulation Baseboard platform. | |
| config REALVIEW_EB_A9MP | |
| bool "Support Multicore Cortex-A9 Tile" | |
| depends on MACH_REALVIEW_EB && ARCH_MULTI_V7 | |
| help | |
| Enable support for the Cortex-A9MPCore tile fitted to the | |
| Realview(R) Emulation Baseboard platform. | |
| config REALVIEW_EB_ARM11MP | |
| bool "Support ARM11MPCore Tile" | |
| depends on MACH_REALVIEW_EB && ARCH_MULTI_V6 | |
| select HAVE_SMP | |
| help | |
| Enable support for the ARM11MPCore tile fitted to the Realview(R) | |
| Emulation Baseboard platform. | |
| config MACH_REALVIEW_PB11MP | |
| bool "Support RealView(R) Platform Baseboard for ARM11MPCore" | |
| depends on ARCH_MULTI_V6 | |
| select HAVE_SMP | |
| help | |
| Include support for the ARM(R) RealView(R) Platform Baseboard for | |
| the ARM11MPCore. This platform has an on-board ARM11MPCore and has | |
| support for PCI-E and Compact Flash. | |
| # ARMv6 CPU without K extensions, but does have the new exclusive ops | |
| config MACH_REALVIEW_PB1176 | |
| bool "Support RealView(R) Platform Baseboard for ARM1176JZF-S" | |
| depends on ARCH_MULTI_V6 | |
| select CPU_V6 | |
| select HAVE_TCM | |
| help | |
| Include support for the ARM(R) RealView(R) Platform Baseboard for | |
| ARM1176JZF-S. | |
| config MACH_REALVIEW_PBA8 | |
| bool "Support RealView(R) Platform Baseboard for Cortex(tm)-A8 platform" | |
| depends on ARCH_MULTI_V7 | |
| help | |
| Include support for the ARM(R) RealView Platform Baseboard for | |
| Cortex(tm)-A8. This platform has an on-board Cortex-A8 and has | |
| support for PCI-E and Compact Flash. | |
| config MACH_REALVIEW_PBX | |
| bool "Support RealView(R) Platform Baseboard Explore for Cortex-A9" | |
| depends on ARCH_MULTI_V7 | |
| select ZONE_DMA | |
| help | |
| Include support for the ARM(R) RealView(R) Platform Baseboard | |
| Explore. | |
| endif | |
| menuconfig ARCH_VEXPRESS | |
| bool "ARM Ltd. Versatile Express family" | |
| depends on ARCH_MULTI_V7 | |
| select ARM_AMBA | |
| select ARM_GIC | |
| select ARM_GLOBAL_TIMER | |
| select ARM_TIMER_SP804 | |
| select GPIOLIB | |
| select HAVE_ARM_SCU if SMP | |
| select HAVE_ARM_TWD if SMP | |
| select HAVE_PATA_PLATFORM | |
| select CLK_ICST | |
| select NO_IOPORT_MAP | |
| select PLAT_VERSATILE | |
| select POWER_RESET | |
| select POWER_RESET_VEXPRESS | |
| select POWER_SUPPLY | |
| select REGULATOR if MMC_ARMMMCI | |
| select REGULATOR_FIXED_VOLTAGE if REGULATOR | |
| select VEXPRESS_CONFIG | |
| help | |
| This option enables support for systems using Cortex processor based | |
| ARM core and logic (FPGA) tiles on the Versatile Express motherboard, | |
| for example: | |
| - CoreTile Express A5x2 (V2P-CA5s) | |
| - CoreTile Express A9x4 (V2P-CA9) | |
| - CoreTile Express A15x2 (V2P-CA15) | |
| - LogicTile Express 13MG (V2F-2XV6) with A5, A7, A9 or A15 SMMs | |
| (Soft Macrocell Models) | |
| - Versatile Express RTSMs (Models) | |
| You must boot using a Flattened Device Tree in order to use these | |
| platforms. The traditional (ATAGs) boot method is not usable on | |
| these boards with this option. | |
| if ARCH_VEXPRESS | |
| config ARCH_VEXPRESS_CORTEX_A5_A9_ERRATA | |
| bool "Enable A5 and A9 only errata work-arounds" | |
| default y | |
| select ARM_ERRATA_643719 if SMP | |
| select ARM_ERRATA_720789 | |
| select PL310_ERRATA_753970 if CACHE_L2X0 | |
| help | |
| Provides common dependencies for Versatile Express platforms | |
| based on Cortex-A5 and Cortex-A9 processors. In order to | |
| build a working kernel, you must also enable relevant core | |
| tile support or Flattened Device Tree based support options. | |
| config ARCH_VEXPRESS_DCSCB | |
| bool "Dual Cluster System Control Block (DCSCB) support" | |
| depends on MCPM | |
| select ARM_CCI400_PORT_CTRL | |
| help | |
| Support for the Dual Cluster System Configuration Block (DCSCB). | |
| This is needed to provide CPU and cluster power management | |
| on RTSM implementing big.LITTLE. | |
| config ARCH_VEXPRESS_SPC | |
| bool "Versatile Express Serial Power Controller (SPC)" | |
| select PM_OPP | |
| help | |
| The TC2 (A15x2 A7x3) versatile express core tile integrates a logic | |
| block called Serial Power Controller (SPC) that provides the interface | |
| between the dual cluster test-chip and the M3 microcontroller that | |
| carries out power management. | |
| config ARCH_VEXPRESS_TC2_PM | |
| bool "Versatile Express TC2 power management" | |
| depends on MCPM | |
| select ARM_CCI400_PORT_CTRL | |
| select ARCH_VEXPRESS_SPC | |
| select ARM_CPU_SUSPEND | |
| help | |
| Support for CPU and cluster power management on Versatile Express | |
| with a TC2 (A15x2 A7x3) big.LITTLE core tile. | |
| endif |