| What: /sys/firmware/sgi_uv/ | |
| Date: September 2020 | |
| Contact: Justin Ernst <justin.ernst@hpe.com> | |
| Description: | |
| The /sys/firmware/sgi_uv directory contains information | |
| about the UV platform. | |
| Under that directory are a number of read-only attributes:: | |
| archtype | |
| hub_type | |
| hubless | |
| partition_id | |
| coherence_id | |
| uv_type | |
| The archtype entry contains the UV architecture type that | |
| is used to select arch-dependent addresses and features. | |
| It can be set via the OEM_ID in the ACPI MADT table or by | |
| UVsystab entry both passed from UV BIOS. | |
| The hub_type entry is used to select the type of hub which is | |
| similar to uv_type but encoded in a binary format. Include | |
| the file uv_hub.h to get the definitions. | |
| The hubless entry basically is present and set only if there | |
| is no hub. In this case the hub_type entry is not present. | |
| The partition_id entry contains the partition id. | |
| UV systems can be partitioned into multiple physical | |
| machines, which each partition running a unique copy | |
| of the operating system. Each partition will have a unique | |
| partition id. | |
| The coherence_id entry contains the coherence id. | |
| A partitioned UV system can have one or more coherence | |
| domains. The coherence id indicates which coherence domain | |
| this partition is in. | |
| The uv_type entry contains the hub revision number. | |
| This value can be used to identify the UV system version:: | |
| "0.*" = Hubless UV ('*' is subtype) | |
| "3.0" = UV2 | |
| "5.0" = UV3 | |
| "7.0" = UV4 | |
| "7.1" = UV4a | |
| "9.0" = UV5 | |
| The /sys/firmware/sgi_uv directory also contains two directories:: | |
| hubs/ | |
| pcibuses/ | |
| The hubs directory contains a number of hub objects, each representing | |
| a UV Hub visible to the BIOS. Each hub object's name is appended by a | |
| unique ordinal value (ex. /sys/firmware/sgi_uv/hubs/hub_5) | |
| Each hub object directory contains a number of read-only attributes:: | |
| cnode | |
| location | |
| name | |
| nasid | |
| shared | |
| this_partition | |
| The cnode entry contains the cnode number of the corresponding hub. | |
| If a cnode value is not applicable, the value returned will be -1. | |
| The location entry contains the location string of the corresponding hub. | |
| This value is used to physically identify a hub within a system. | |
| The name entry contains the name of the corresponding hub. This name can | |
| be two variants:: | |
| "UVHub x.x" = A 'node' ASIC, connecting a CPU to the interconnect | |
| fabric. The 'x.x' value represents the ASIC revision. | |
| (ex. 'UVHub 5.0') | |
| "NLxRouter" = A 'router ASIC, only connecting other ASICs to | |
| the interconnect fabric. The 'x' value representing | |
| the fabric technology version. (ex. 'NL8Router') | |
| The nasid entry contains the nasid number of the corresponding hub. | |
| If a nasid value is not applicable, the value returned will be -1. | |
| The shared entry contains a boolean value describing whether the | |
| corresponding hub is shared between system partitions. | |
| The this_partition entry contains a boolean value describing whether | |
| the corresponding hub is local to the current partition. | |
| Each hub object directory also contains a number of port objects, | |
| each representing a fabric port on the corresponding hub. | |
| A port object's name is appended by a unique ordinal value | |
| (ex. /sys/firmware/sgi_uv/hubs/hub_5/port_3) | |
| Each port object directory contains a number of read-only attributes:: | |
| conn_hub | |
| conn_port | |
| The conn_hub entry contains a value representing the unique | |
| oridinal value of the hub on the other end of the fabric | |
| cable plugged into the port. If the port is disconnected, | |
| the value returned will be -1. | |
| The conn_port entry contains a value representing the unique | |
| oridinal value of the port on the other end of the fabric cable | |
| plugged into the port. If the port is disconnected, the value | |
| returned will be -1. | |
| Ex: | |
| A value of '3' is read from: | |
| /sys/firmware/sgi_uv/hubs/hub_5/port_3/conn_hub | |
| and a value of '6' is read from: | |
| /sys/firmware/sgi_uv/hubs/hub_5/port_3/conn_port | |
| representing that this port is connected to: | |
| /sys/firmware/sgi_uv/hubs/hub_3/port_6 | |
| The pcibuses directory contains a number of PCI bus objects. | |
| Each PCI bus object's name is appended by its PCI bus address. | |
| (ex. pcibus_0003:80) | |
| Each pcibus object has a number of possible read-only attributes:: | |
| type | |
| location | |
| slot | |
| ppb_addr | |
| iio_stack | |
| The type entry contains a value describing the type of IO at | |
| the corresponding PCI bus address. Known possible values | |
| across all UV versions are:: | |
| BASE IO | |
| PCIe IO | |
| PCIe SLOT | |
| NODE IO | |
| Riser | |
| PPB | |
| The location entry contains the location string of the UV Hub | |
| of the CPU physically connected to the corresponding PCI bus. | |
| The slot entry contains the physical slot number of the | |
| corresponding PCI bus. This value is used to physically locate | |
| PCI cards within a system. | |
| The ppb_addr entry contains the PCI address string of the | |
| bridged PCI bus. This entry is only present when the PCI bus | |
| object type is 'PPB'. | |
| The iio_stack entry contains a value describing the IIO stack | |