| NVIDIA Tegra241 SoC Uncore Performance Monitoring Unit (PMU) | |
| ============================================================ | |
| The NVIDIA Tegra241 SoC includes various system PMUs to measure key performance | |
| metrics like memory bandwidth, latency, and utilization: | |
| * Scalable Coherency Fabric (SCF) | |
| * NVLink-C2C0 | |
| * NVLink-C2C1 | |
| * CNVLink | |
| * PCIE | |
| PMU Driver | |
| ---------- | |
| The PMUs in this document are based on ARM CoreSight PMU Architecture as | |
| described in document: ARM IHI 0091. Since this is a standard architecture, the | |
| PMUs are managed by a common driver "arm-cs-arch-pmu". This driver describes | |
| the available events and configuration of each PMU in sysfs. Please see the | |
| sections below to get the sysfs path of each PMU. Like other uncore PMU drivers, | |
| the driver provides "cpumask" sysfs attribute to show the CPU id used to handle | |
| the PMU event. There is also "associated_cpus" sysfs attribute, which contains a | |
| list of CPUs associated with the PMU instance. | |
| .. _SCF_PMU_Section: | |
| SCF PMU | |
| ------- | |
| The SCF PMU monitors system level cache events, CPU traffic, and | |
| strongly-ordered (SO) PCIE write traffic to local/remote memory. Please see | |
| :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about the PMU | |
| traffic coverage. | |
| The events and configuration options of this PMU device are described in sysfs, | |
| see /sys/bus/event_source/devices/nvidia_scf_pmu_<socket-id>. | |
| Example usage: | |
| * Count event id 0x0 in socket 0:: | |
| perf stat -a -e nvidia_scf_pmu_0/event=0x0/ | |
| * Count event id 0x0 in socket 1:: | |
| perf stat -a -e nvidia_scf_pmu_1/event=0x0/ | |
| NVLink-C2C0 PMU | |
| -------------------- | |
| The NVLink-C2C0 PMU monitors incoming traffic from a GPU/CPU connected with | |
| NVLink-C2C (Chip-2-Chip) interconnect. The type of traffic captured by this PMU | |
| varies dependent on the chip configuration: | |
| * NVIDIA Grace Hopper Superchip: Hopper GPU is connected with Grace SoC. | |
| In this config, the PMU captures GPU ATS translated or EGM traffic from the GPU. | |
| * NVIDIA Grace CPU Superchip: two Grace CPU SoCs are connected. | |
| In this config, the PMU captures read and relaxed ordered (RO) writes from | |
| PCIE device of the remote SoC. | |
| Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about | |
| the PMU traffic coverage. | |
| The events and configuration options of this PMU device are described in sysfs, | |
| see /sys/bus/event_source/devices/nvidia_nvlink_c2c0_pmu_<socket-id>. | |
| Example usage: | |
| * Count event id 0x0 from the GPU/CPU connected with socket 0:: | |
| perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0/ | |
| * Count event id 0x0 from the GPU/CPU connected with socket 1:: | |
| perf stat -a -e nvidia_nvlink_c2c0_pmu_1/event=0x0/ | |
| * Count event id 0x0 from the GPU/CPU connected with socket 2:: | |
| perf stat -a -e nvidia_nvlink_c2c0_pmu_2/event=0x0/ | |
| * Count event id 0x0 from the GPU/CPU connected with socket 3:: | |
| perf stat -a -e nvidia_nvlink_c2c0_pmu_3/event=0x0/ | |
| The NVLink-C2C has two ports that can be connected to one GPU (occupying both | |
| ports) or to two GPUs (one GPU per port). The user can use "port" bitmap | |
| parameter to select the port(s) to monitor. Each bit represents the port number, | |
| e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. The | |
| PMU will monitor both ports by default if not specified. | |
| Example for port filtering: | |
| * Count event id 0x0 from the GPU connected with socket 0 on port 0:: | |
| perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0,port=0x1/ | |
| * Count event id 0x0 from the GPUs connected with socket 0 on port 0 and port 1:: | |
| perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0,port=0x3/ | |
| NVLink-C2C1 PMU | |
| ------------------- | |
| The NVLink-C2C1 PMU monitors incoming traffic from a GPU connected with | |
| NVLink-C2C (Chip-2-Chip) interconnect. This PMU captures untranslated GPU | |
| traffic, in contrast with NvLink-C2C0 PMU that captures ATS translated traffic. | |
| Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about | |
| the PMU traffic coverage. | |
| The events and configuration options of this PMU device are described in sysfs, | |
| see /sys/bus/event_source/devices/nvidia_nvlink_c2c1_pmu_<socket-id>. | |
| Example usage: | |
| * Count event id 0x0 from the GPU connected with socket 0:: | |
| perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0/ | |
| * Count event id 0x0 from the GPU connected with socket 1:: | |
| perf stat -a -e nvidia_nvlink_c2c1_pmu_1/event=0x0/ | |
| * Count event id 0x0 from the GPU connected with socket 2:: | |
| perf stat -a -e nvidia_nvlink_c2c1_pmu_2/event=0x0/ | |
| * Count event id 0x0 from the GPU connected with socket 3:: | |
| perf stat -a -e nvidia_nvlink_c2c1_pmu_3/event=0x0/ | |
| The NVLink-C2C has two ports that can be connected to one GPU (occupying both | |
| ports) or to two GPUs (one GPU per port). The user can use "port" bitmap | |
| parameter to select the port(s) to monitor. Each bit represents the port number, | |
| e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. The | |
| PMU will monitor both ports by default if not specified. | |
| Example for port filtering: | |
| * Count event id 0x0 from the GPU connected with socket 0 on port 0:: | |
| perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0,port=0x1/ | |
| * Count event id 0x0 from the GPUs connected with socket 0 on port 0 and port 1:: | |
| perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0,port=0x3/ | |
| CNVLink PMU | |
| --------------- | |
| The CNVLink PMU monitors traffic from GPU and PCIE device on remote sockets | |
| to local memory. For PCIE traffic, this PMU captures read and relaxed ordered | |
| (RO) write traffic. Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` | |
| for more info about the PMU traffic coverage. | |
| The events and configuration options of this PMU device are described in sysfs, | |
| see /sys/bus/event_source/devices/nvidia_cnvlink_pmu_<socket-id>. | |
| Each SoC socket can be connected to one or more sockets via CNVLink. The user can | |
| use "rem_socket" bitmap parameter to select the remote socket(s) to monitor. | |
| Each bit represents the socket number, e.g. "rem_socket=0xE" corresponds to | |
| socket 1 to 3. The PMU will monitor all remote sockets by default if not | |
| specified. | |
| /sys/bus/event_source/devices/nvidia_cnvlink_pmu_<socket-id>/format/rem_socket | |
| shows the valid bits that can be set in the "rem_socket" parameter. | |
| The PMU can not distinguish the remote traffic initiator, therefore it does not | |
| provide filter to select the traffic source to monitor. It reports combined | |
| traffic from remote GPU and PCIE devices. | |
| Example usage: | |
| * Count event id 0x0 for the traffic from remote socket 1, 2, and 3 to socket 0:: | |
| perf stat -a -e nvidia_cnvlink_pmu_0/event=0x0,rem_socket=0xE/ | |
| * Count event id 0x0 for the traffic from remote socket 0, 2, and 3 to socket 1:: | |
| perf stat -a -e nvidia_cnvlink_pmu_1/event=0x0,rem_socket=0xD/ | |
| * Count event id 0x0 for the traffic from remote socket 0, 1, and 3 to socket 2:: | |
| perf stat -a -e nvidia_cnvlink_pmu_2/event=0x0,rem_socket=0xB/ | |
| * Count event id 0x0 for the traffic from remote socket 0, 1, and 2 to socket 3:: | |
| perf stat -a -e nvidia_cnvlink_pmu_3/event=0x0,rem_socket=0x7/ | |
| PCIE PMU | |
| ------------ | |
| The PCIE PMU monitors all read/write traffic from PCIE root ports to | |
| local/remote memory. Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` | |
| for more info about the PMU traffic coverage. | |
| The events and configuration options of this PMU device are described in sysfs, | |
| see /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>. | |
| Each SoC socket can support multiple root ports. The user can use | |
| "root_port" bitmap parameter to select the port(s) to monitor, i.e. | |
| "root_port=0xF" corresponds to root port 0 to 3. The PMU will monitor all root | |
| ports by default if not specified. | |
| /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>/format/root_port | |
| shows the valid bits that can be set in the "root_port" parameter. | |
| Example usage: | |
| * Count event id 0x0 from root port 0 and 1 of socket 0:: | |
| perf stat -a -e nvidia_pcie_pmu_0/event=0x0,root_port=0x3/ | |
| * Count event id 0x0 from root port 0 and 1 of socket 1:: | |
| perf stat -a -e nvidia_pcie_pmu_1/event=0x0,root_port=0x3/ | |
| .. _NVIDIA_Uncore_PMU_Traffic_Coverage_Section: | |
| Traffic Coverage | |
| ---------------- | |
| The PMU traffic coverage may vary dependent on the chip configuration: | |
| * **NVIDIA Grace Hopper Superchip**: Hopper GPU is connected with Grace SoC. | |
| Example configuration with two Grace SoCs:: | |
| ********************************* ********************************* | |
| * SOCKET-A * * SOCKET-B * | |
| * * * * | |
| * :::::::: * * :::::::: * | |
| * : PCIE : * * : PCIE : * | |
| * :::::::: * * :::::::: * | |
| * | * * | * | |
| * | * * | * | |
| * ::::::: ::::::::: * * ::::::::: ::::::: * | |
| * : : : : * * : : : : * | |
| * : GPU :<--NVLink-->: Grace :<---CNVLink--->: Grace :<--NVLink-->: GPU : * | |
| * : : C2C : SoC : * * : SoC : C2C : : * | |
| * ::::::: ::::::::: * * ::::::::: ::::::: * | |
| * | | * * | | * | |
| * | | * * | | * | |
| * &&&&&&&& &&&&&&&& * * &&&&&&&& &&&&&&&& * | |
| * & GMEM & & CMEM & * * & CMEM & & GMEM & * | |
| * &&&&&&&& &&&&&&&& * * &&&&&&&& &&&&&&&& * | |
| * * * * | |
| ********************************* ********************************* | |
| GMEM = GPU Memory (e.g. HBM) | |
| CMEM = CPU Memory (e.g. LPDDR5X) | |
| | | |
| | Following table contains traffic coverage of Grace SoC PMU in socket-A: | |
| :: | |
| +--------------+-------+-----------+-----------+-----+----------+----------+ | |
| | | Source | | |
| + +-------+-----------+-----------+-----+----------+----------+ | |
| | Destination | |GPU ATS |GPU Not-ATS| | Socket-B | Socket-B | | |
| | |PCI R/W|Translated,|Translated | CPU | CPU/PCIE1| GPU/PCIE2| | |
| | | |EGM | | | | | | |
| +==============+=======+===========+===========+=====+==========+==========+ | |
| | Local | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | SCF PMU | CNVLink | | |
| | SYSRAM/CMEM | PMU |PMU |PMU | PMU | | PMU | | |
| +--------------+-------+-----------+-----------+-----+----------+----------+ | |
| | Local GMEM | PCIE | N/A |NVLink-C2C1| SCF | SCF PMU | CNVLink | | |
| | | PMU | |PMU | PMU | | PMU | | |
| +--------------+-------+-----------+-----------+-----+----------+----------+ | |
| | Remote | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | | | | |
| | SYSRAM/CMEM | PMU |PMU |PMU | PMU | N/A | N/A | | |
| | over CNVLink | | | | | | | | |
| +--------------+-------+-----------+-----------+-----+----------+----------+ | |
| | Remote GMEM | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | | | | |
| | over CNVLink | PMU |PMU |PMU | PMU | N/A | N/A | | |
| +--------------+-------+-----------+-----------+-----+----------+----------+ | |
| PCIE1 traffic represents strongly ordered (SO) writes. | |
| PCIE2 traffic represents reads and relaxed ordered (RO) writes. | |
| * **NVIDIA Grace CPU Superchip**: two Grace CPU SoCs are connected. | |
| Example configuration with two Grace SoCs:: | |
| ******************* ******************* | |
| * SOCKET-A * * SOCKET-B * | |
| * * * * | |
| * :::::::: * * :::::::: * | |
| * : PCIE : * * : PCIE : * | |
| * :::::::: * * :::::::: * | |
| * | * * | * | |
| * | * * | * | |
| * ::::::::: * * ::::::::: * | |
| * : : * * : : * | |
| * : Grace :<--------NVLink------->: Grace : * | |
| * : SoC : * C2C * : SoC : * | |
| * ::::::::: * * ::::::::: * | |
| * | * * | * | |
| * | * * | * | |
| * &&&&&&&& * * &&&&&&&& * | |
| * & CMEM & * * & CMEM & * | |
| * &&&&&&&& * * &&&&&&&& * | |
| * * * * | |
| ******************* ******************* | |
| GMEM = GPU Memory (e.g. HBM) | |
| CMEM = CPU Memory (e.g. LPDDR5X) | |
| | | |
| | Following table contains traffic coverage of Grace SoC PMU in socket-A: | |
| :: | |
| +-----------------+-----------+---------+----------+-------------+ | |
| | | Source | | |
| + +-----------+---------+----------+-------------+ | |
| | Destination | | | Socket-B | Socket-B | | |
| | | PCI R/W | CPU | CPU/PCIE1| PCIE2 | | |
| | | | | | | | |
| +=================+===========+=========+==========+=============+ | |
| | Local | PCIE PMU | SCF PMU | SCF PMU | NVLink-C2C0 | | |
| | SYSRAM/CMEM | | | | PMU | | |
| +-----------------+-----------+---------+----------+-------------+ | |
| | Remote | | | | | | |
| | SYSRAM/CMEM | PCIE PMU | SCF PMU | N/A | N/A | | |
| | over NVLink-C2C | | | | | | |
| +-----------------+-----------+---------+----------+-------------+ | |
| PCIE1 traffic represents strongly ordered (SO) writes. | |
| PCIE2 traffic represents reads and relaxed ordered (RO) writes. |