| // SPDX-License-Identifier: GPL-2.0+ | |
| /* | |
| * hdc2010.c - Support for the TI HDC2010 and HDC2080 | |
| * temperature + relative humidity sensors | |
| * | |
| * Copyright (C) 2020 Norphonic AS | |
| * Author: Eugene Zaikonnikov <ez@norphonic.com> | |
| * | |
| * Datasheet: https://www.ti.com/product/HDC2010/datasheet | |
| * Datasheet: https://www.ti.com/product/HDC2080/datasheet | |
| */ | |
| #include <linux/module.h> | |
| #include <linux/init.h> | |
| #include <linux/i2c.h> | |
| #include <linux/bitops.h> | |
| #include <linux/iio/iio.h> | |
| #include <linux/iio/sysfs.h> | |
| #define HDC2010_REG_TEMP_LOW 0x00 | |
| #define HDC2010_REG_TEMP_HIGH 0x01 | |
| #define HDC2010_REG_HUMIDITY_LOW 0x02 | |
| #define HDC2010_REG_HUMIDITY_HIGH 0x03 | |
| #define HDC2010_REG_INTERRUPT_DRDY 0x04 | |
| #define HDC2010_REG_TEMP_MAX 0x05 | |
| #define HDC2010_REG_HUMIDITY_MAX 0x06 | |
| #define HDC2010_REG_INTERRUPT_EN 0x07 | |
| #define HDC2010_REG_TEMP_OFFSET_ADJ 0x08 | |
| #define HDC2010_REG_HUMIDITY_OFFSET_ADJ 0x09 | |
| #define HDC2010_REG_TEMP_THR_L 0x0a | |
| #define HDC2010_REG_TEMP_THR_H 0x0b | |
| #define HDC2010_REG_RH_THR_L 0x0c | |
| #define HDC2010_REG_RH_THR_H 0x0d | |
| #define HDC2010_REG_RESET_DRDY_INT_CONF 0x0e | |
| #define HDC2010_REG_MEASUREMENT_CONF 0x0f | |
| #define HDC2010_MEAS_CONF GENMASK(2, 1) | |
| #define HDC2010_MEAS_TRIG BIT(0) | |
| #define HDC2010_HEATER_EN BIT(3) | |
| #define HDC2010_AMM GENMASK(6, 4) | |
| struct hdc2010_data { | |
| struct i2c_client *client; | |
| struct mutex lock; | |
| u8 measurement_config; | |
| u8 drdy_config; | |
| }; | |
| enum hdc2010_addr_groups { | |
| HDC2010_GROUP_TEMP = 0, | |
| HDC2010_GROUP_HUMIDITY, | |
| }; | |
| struct hdc2010_reg_record { | |
| unsigned long primary; | |
| unsigned long peak; | |
| }; | |
| static const struct hdc2010_reg_record hdc2010_reg_translation[] = { | |
| [HDC2010_GROUP_TEMP] = { | |
| .primary = HDC2010_REG_TEMP_LOW, | |
| .peak = HDC2010_REG_TEMP_MAX, | |
| }, | |
| [HDC2010_GROUP_HUMIDITY] = { | |
| .primary = HDC2010_REG_HUMIDITY_LOW, | |
| .peak = HDC2010_REG_HUMIDITY_MAX, | |
| }, | |
| }; | |
| static IIO_CONST_ATTR(out_current_heater_raw_available, "0 1"); | |
| static struct attribute *hdc2010_attributes[] = { | |
| &iio_const_attr_out_current_heater_raw_available.dev_attr.attr, | |
| NULL | |
| }; | |
| static const struct attribute_group hdc2010_attribute_group = { | |
| .attrs = hdc2010_attributes, | |
| }; | |
| static const struct iio_chan_spec hdc2010_channels[] = { | |
| { | |
| .type = IIO_TEMP, | |
| .address = HDC2010_GROUP_TEMP, | |
| .info_mask_separate = BIT(IIO_CHAN_INFO_RAW) | | |
| BIT(IIO_CHAN_INFO_PEAK) | | |
| BIT(IIO_CHAN_INFO_OFFSET) | | |
| BIT(IIO_CHAN_INFO_SCALE), | |
| }, | |
| { | |
| .type = IIO_HUMIDITYRELATIVE, | |
| .address = HDC2010_GROUP_HUMIDITY, | |
| .info_mask_separate = BIT(IIO_CHAN_INFO_RAW) | | |
| BIT(IIO_CHAN_INFO_PEAK) | | |
| BIT(IIO_CHAN_INFO_SCALE), | |
| }, | |
| { | |
| .type = IIO_CURRENT, | |
| .info_mask_separate = BIT(IIO_CHAN_INFO_RAW), | |
| .extend_name = "heater", | |
| .output = 1, | |
| }, | |
| }; | |
| static int hdc2010_update_drdy_config(struct hdc2010_data *data, | |
| char mask, char val) | |
| { | |
| u8 tmp = (~mask & data->drdy_config) | val; | |
| int ret; | |
| ret = i2c_smbus_write_byte_data(data->client, | |
| HDC2010_REG_RESET_DRDY_INT_CONF, tmp); | |
| if (ret) | |
| return ret; | |
| data->drdy_config = tmp; | |
| return 0; | |
| } | |
| static int hdc2010_get_prim_measurement_word(struct hdc2010_data *data, | |
| struct iio_chan_spec const *chan) | |
| { | |
| struct i2c_client *client = data->client; | |
| s32 ret; | |
| ret = i2c_smbus_read_word_data(client, | |
| hdc2010_reg_translation[chan->address].primary); | |
| if (ret < 0) | |
| dev_err(&client->dev, "Could not read sensor measurement word\n"); | |
| return ret; | |
| } | |
| static int hdc2010_get_peak_measurement_byte(struct hdc2010_data *data, | |
| struct iio_chan_spec const *chan) | |
| { | |
| struct i2c_client *client = data->client; | |
| s32 ret; | |
| ret = i2c_smbus_read_byte_data(client, | |
| hdc2010_reg_translation[chan->address].peak); | |
| if (ret < 0) | |
| dev_err(&client->dev, "Could not read sensor measurement byte\n"); | |
| return ret; | |
| } | |
| static int hdc2010_get_heater_status(struct hdc2010_data *data) | |
| { | |
| return !!(data->drdy_config & HDC2010_HEATER_EN); | |
| } | |
| static int hdc2010_read_raw(struct iio_dev *indio_dev, | |
| struct iio_chan_spec const *chan, int *val, | |
| int *val2, long mask) | |
| { | |
| struct hdc2010_data *data = iio_priv(indio_dev); | |
| switch (mask) { | |
| case IIO_CHAN_INFO_RAW: { | |
| int ret; | |
| if (chan->type == IIO_CURRENT) { | |
| *val = hdc2010_get_heater_status(data); | |
| return IIO_VAL_INT; | |
| } | |
| if (!iio_device_claim_direct(indio_dev)) | |
| return -EBUSY; | |
| mutex_lock(&data->lock); | |
| ret = hdc2010_get_prim_measurement_word(data, chan); | |
| mutex_unlock(&data->lock); | |
| iio_device_release_direct(indio_dev); | |
| if (ret < 0) | |
| return ret; | |
| *val = ret; | |
| return IIO_VAL_INT; | |
| } | |
| case IIO_CHAN_INFO_PEAK: { | |
| int ret; | |
| if (!iio_device_claim_direct(indio_dev)) | |
| return -EBUSY; | |
| mutex_lock(&data->lock); | |
| ret = hdc2010_get_peak_measurement_byte(data, chan); | |
| mutex_unlock(&data->lock); | |
| iio_device_release_direct(indio_dev); | |
| if (ret < 0) | |
| return ret; | |
| /* Scaling up the value so we can use same offset as RAW */ | |
| *val = ret * 256; | |
| return IIO_VAL_INT; | |
| } | |
| case IIO_CHAN_INFO_SCALE: | |
| *val2 = 65536; | |
| if (chan->type == IIO_TEMP) | |
| *val = 165000; | |
| else | |
| *val = 100000; | |
| return IIO_VAL_FRACTIONAL; | |
| case IIO_CHAN_INFO_OFFSET: | |
| *val = -15887; | |
| *val2 = 515151; | |
| return IIO_VAL_INT_PLUS_MICRO; | |
| default: | |
| return -EINVAL; | |
| } | |
| } | |
| static int hdc2010_write_raw(struct iio_dev *indio_dev, | |
| struct iio_chan_spec const *chan, | |
| int val, int val2, long mask) | |
| { | |
| struct hdc2010_data *data = iio_priv(indio_dev); | |
| int new, ret; | |
| switch (mask) { | |
| case IIO_CHAN_INFO_RAW: | |
| if (chan->type != IIO_CURRENT || val2 != 0) | |
| return -EINVAL; | |
| switch (val) { | |
| case 1: | |
| new = HDC2010_HEATER_EN; | |
| break; | |
| case 0: | |
| new = 0; | |
| break; | |
| default: | |
| return -EINVAL; | |
| } | |
| mutex_lock(&data->lock); | |
| ret = hdc2010_update_drdy_config(data, HDC2010_HEATER_EN, new); | |
| mutex_unlock(&data->lock); | |
| return ret; | |
| default: | |
| return -EINVAL; | |
| } | |
| } | |
| static const struct iio_info hdc2010_info = { | |
| .read_raw = hdc2010_read_raw, | |
| .write_raw = hdc2010_write_raw, | |
| .attrs = &hdc2010_attribute_group, | |
| }; | |
| static int hdc2010_probe(struct i2c_client *client) | |
| { | |
| struct iio_dev *indio_dev; | |
| struct hdc2010_data *data; | |
| u8 tmp; | |
| int ret; | |
| if (!i2c_check_functionality(client->adapter, | |
| I2C_FUNC_SMBUS_WORD_DATA | I2C_FUNC_SMBUS_BYTE | I2C_FUNC_I2C)) | |
| return -EOPNOTSUPP; | |
| indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*data)); | |
| if (!indio_dev) | |
| return -ENOMEM; | |
| data = iio_priv(indio_dev); | |
| i2c_set_clientdata(client, indio_dev); | |
| data->client = client; | |
| mutex_init(&data->lock); | |
| /* | |
| * As DEVICE ID register does not differentiate between | |
| * HDC2010 and HDC2080, we have the name hardcoded | |
| */ | |
| indio_dev->name = "hdc2010"; | |
| indio_dev->modes = INDIO_DIRECT_MODE; | |
| indio_dev->info = &hdc2010_info; | |
| indio_dev->channels = hdc2010_channels; | |
| indio_dev->num_channels = ARRAY_SIZE(hdc2010_channels); | |
| /* Enable Automatic Measurement Mode at 5Hz */ | |
| ret = hdc2010_update_drdy_config(data, HDC2010_AMM, HDC2010_AMM); | |
| if (ret) | |
| return ret; | |
| /* | |
| * We enable both temp and humidity measurement. | |
| * However the measurement won't start even in AMM until triggered. | |
| */ | |
| tmp = (data->measurement_config & ~HDC2010_MEAS_CONF) | | |
| HDC2010_MEAS_TRIG; | |
| ret = i2c_smbus_write_byte_data(client, HDC2010_REG_MEASUREMENT_CONF, tmp); | |
| if (ret) { | |
| dev_warn(&client->dev, "Unable to set up measurement\n"); | |
| if (hdc2010_update_drdy_config(data, HDC2010_AMM, 0)) | |
| dev_warn(&client->dev, "Unable to restore default AMM\n"); | |
| return ret; | |
| } | |
| data->measurement_config = tmp; | |
| return iio_device_register(indio_dev); | |
| } | |
| static void hdc2010_remove(struct i2c_client *client) | |
| { | |
| struct iio_dev *indio_dev = i2c_get_clientdata(client); | |
| struct hdc2010_data *data = iio_priv(indio_dev); | |
| iio_device_unregister(indio_dev); | |
| /* Disable Automatic Measurement Mode */ | |
| if (hdc2010_update_drdy_config(data, HDC2010_AMM, 0)) | |
| dev_warn(&client->dev, "Unable to restore default AMM\n"); | |
| } | |
| static const struct i2c_device_id hdc2010_id[] = { | |
| { .name = "hdc2010" }, | |
| { .name = "hdc2080" }, | |
| { } | |
| }; | |
| MODULE_DEVICE_TABLE(i2c, hdc2010_id); | |
| static const struct of_device_id hdc2010_dt_ids[] = { | |
| { .compatible = "ti,hdc2010" }, | |
| { .compatible = "ti,hdc2080" }, | |
| { } | |
| }; | |
| MODULE_DEVICE_TABLE(of, hdc2010_dt_ids); | |
| static struct i2c_driver hdc2010_driver = { | |
| .driver = { | |
| .name = "hdc2010", | |
| .of_match_table = hdc2010_dt_ids, | |
| }, | |
| .probe = hdc2010_probe, | |
| .remove = hdc2010_remove, | |
| .id_table = hdc2010_id, | |
| }; | |
| module_i2c_driver(hdc2010_driver); | |
| MODULE_AUTHOR("Eugene Zaikonnikov <ez@norphonic.com>"); | |
| MODULE_DESCRIPTION("TI HDC2010 humidity and temperature sensor driver"); | |
| MODULE_LICENSE("GPL"); |