| /* SPDX-License-Identifier: GPL-2.0 */ | |
| #ifndef __SPARC_MMAN_H__ | |
| #define __SPARC_MMAN_H__ | |
| #include <uapi/asm/mman.h> | |
| #ifndef __ASSEMBLER__ | |
| #define arch_mmap_check(addr,len,flags) sparc_mmap_check(addr,len) | |
| int sparc_mmap_check(unsigned long addr, unsigned long len); | |
| #ifdef CONFIG_SPARC64 | |
| #include <asm/adi_64.h> | |
| static inline void ipi_set_tstate_mcde(void *arg) | |
| { | |
| struct mm_struct *mm = arg; | |
| /* Set TSTATE_MCDE for the task using address map that ADI has been | |
| * enabled on if the task is running. If not, it will be set | |
| * automatically at the next context switch | |
| */ | |
| if (current->mm == mm) { | |
| struct pt_regs *regs; | |
| regs = task_pt_regs(current); | |
| regs->tstate |= TSTATE_MCDE; | |
| } | |
| } | |
| #define arch_calc_vm_prot_bits(prot, pkey) sparc_calc_vm_prot_bits(prot) | |
| static inline vm_flags_t sparc_calc_vm_prot_bits(unsigned long prot) | |
| { | |
| if (adi_capable() && (prot & PROT_ADI)) { | |
| struct pt_regs *regs; | |
| if (!current->mm->context.adi) { | |
| regs = task_pt_regs(current); | |
| regs->tstate |= TSTATE_MCDE; | |
| current->mm->context.adi = true; | |
| on_each_cpu_mask(mm_cpumask(current->mm), | |
| ipi_set_tstate_mcde, current->mm, 0); | |
| } | |
| return VM_SPARC_ADI; | |
| } else { | |
| return 0; | |
| } | |
| } | |
| #define arch_validate_prot(prot, addr) sparc_validate_prot(prot, addr) | |
| static inline int sparc_validate_prot(unsigned long prot, unsigned long addr) | |
| { | |
| if (prot & ~(PROT_READ | PROT_WRITE | PROT_EXEC | PROT_SEM | PROT_ADI)) | |
| return 0; | |
| return 1; | |
| } | |
| #define arch_validate_flags(vm_flags) arch_validate_flags(vm_flags) | |
| /* arch_validate_flags() - Ensure combination of flags is valid for a | |
| * VMA. | |
| */ | |
| static inline bool arch_validate_flags(vm_flags_t vm_flags) | |
| { | |
| /* If ADI is being enabled on this VMA, check for ADI | |
| * capability on the platform and ensure VMA is suitable | |
| * for ADI | |
| */ | |
| if (vm_flags & VM_SPARC_ADI) { | |
| if (!adi_capable()) | |
| return false; | |
| /* ADI can not be enabled on PFN mapped pages */ | |
| if (vm_flags & (VM_PFNMAP | VM_MIXEDMAP)) | |
| return false; | |
| /* Mergeable pages can become unmergeable | |
| * if ADI is enabled on them even if they | |
| * have identical data on them. This can be | |
| * because ADI enabled pages with identical | |
| * data may still not have identical ADI | |
| * tags on them. Disallow ADI on mergeable | |
| * pages. | |
| */ | |
| if (vm_flags & VM_MERGEABLE) | |
| return false; | |
| } | |
| return true; | |
| } | |
| #endif /* CONFIG_SPARC64 */ | |
| #endif /* __ASSEMBLER__ */ | |