| .. include:: <isonum.txt> | |
| ========================================================= | |
| DPAA2 (Data Path Acceleration Architecture Gen2) Overview | |
| ========================================================= | |
| :Copyright: |copy| 2015 Freescale Semiconductor Inc. | |
| :Copyright: |copy| 2018 NXP | |
| This document provides an overview of the Freescale DPAA2 architecture | |
| and how it is integrated into the Linux kernel. | |
| Introduction | |
| ============ | |
| DPAA2 is a hardware architecture designed for high-speeed network | |
| packet processing. DPAA2 consists of sophisticated mechanisms for | |
| processing Ethernet packets, queue management, buffer management, | |
| autonomous L2 switching, virtual Ethernet bridging, and accelerator | |
| (e.g. crypto) sharing. | |
| A DPAA2 hardware component called the Management Complex (or MC) manages the | |
| DPAA2 hardware resources. The MC provides an object-based abstraction for | |
| software drivers to use the DPAA2 hardware. | |
| The MC uses DPAA2 hardware resources such as queues, buffer pools, and | |
| network ports to create functional objects/devices such as network | |
| interfaces, an L2 switch, or accelerator instances. | |
| The MC provides memory-mapped I/O command interfaces (MC portals) | |
| which DPAA2 software drivers use to operate on DPAA2 objects. | |
| The diagram below shows an overview of the DPAA2 resource management | |
| architecture:: | |
| +--------------------------------------+ | |
| | OS | | |
| | DPAA2 drivers | | |
| | | | | |
| +-----------------------------|--------+ | |
| | | |
| | (create,discover,connect | |
| | config,use,destroy) | |
| | | |
| DPAA2 | | |
| +------------------------| mc portal |-+ | |
| | | | | |
| | +- - - - - - - - - - - - -V- - -+ | | |
| | | | | | |
| | | Management Complex (MC) | | | |
| | | | | | |
| | +- - - - - - - - - - - - - - - -+ | | |
| | | | |
| | Hardware Hardware | | |
| | Resources Objects | | |
| | --------- ------- | | |
| | -queues -DPRC | | |
| | -buffer pools -DPMCP | | |
| | -Eth MACs/ports -DPIO | | |
| | -network interface -DPNI | | |
| | profiles -DPMAC | | |
| | -queue portals -DPBP | | |
| | -MC portals ... | | |
| | ... | | |
| | | | |
| +--------------------------------------+ | |
| The MC mediates operations such as create, discover, | |
| connect, configuration, and destroy. Fast-path operations | |
| on data, such as packet transmit/receive, are not mediated by | |
| the MC and are done directly using memory mapped regions in | |
| DPIO objects. | |
| Overview of DPAA2 Objects | |
| ========================= | |
| The section provides a brief overview of some key DPAA2 objects. | |
| A simple scenario is described illustrating the objects involved | |
| in creating a network interfaces. | |
| DPRC (Datapath Resource Container) | |
| ---------------------------------- | |
| A DPRC is a container object that holds all the other | |
| types of DPAA2 objects. In the example diagram below there | |
| are 8 objects of 5 types (DPMCP, DPIO, DPBP, DPNI, and DPMAC) | |
| in the container. | |
| :: | |
| +---------------------------------------------------------+ | |
| | DPRC | | |
| | | | |
| | +-------+ +-------+ +-------+ +-------+ +-------+ | | |
| | | DPMCP | | DPIO | | DPBP | | DPNI | | DPMAC | | | |
| | +-------+ +-------+ +-------+ +---+---+ +---+---+ | | |
| | | DPMCP | | DPIO | | | |
| | +-------+ +-------+ | | |
| | | DPMCP | | | |
| | +-------+ | | |
| | | | |
| +---------------------------------------------------------+ | |
| From the point of view of an OS, a DPRC behaves similar to a plug and | |
| play bus, like PCI. DPRC commands can be used to enumerate the contents | |
| of the DPRC, discover the hardware objects present (including mappable | |
| regions and interrupts). | |
| :: | |
| DPRC.1 (bus) | |
| | | |
| +--+--------+-------+-------+-------+ | |
| | | | | | | |
| DPMCP.1 DPIO.1 DPBP.1 DPNI.1 DPMAC.1 | |
| DPMCP.2 DPIO.2 | |
| DPMCP.3 | |
| Hardware objects can be created and destroyed dynamically, providing | |
| the ability to hot plug/unplug objects in and out of the DPRC. | |
| A DPRC has a mappable MMIO region (an MC portal) that can be used | |
| to send MC commands. It has an interrupt for status events (like | |
| hotplug). | |
| All objects in a container share the same hardware "isolation context". | |
| This means that with respect to an IOMMU the isolation granularity | |
| is at the DPRC (container) level, not at the individual object | |
| level. | |
| DPRCs can be defined statically and populated with objects | |
| via a config file passed to the MC when firmware starts it. | |
| DPAA2 Objects for an Ethernet Network Interface | |
| ----------------------------------------------- | |
| A typical Ethernet NIC is monolithic-- the NIC device contains TX/RX | |
| queuing mechanisms, configuration mechanisms, buffer management, | |
| physical ports, and interrupts. DPAA2 uses a more granular approach | |
| utilizing multiple hardware objects. Each object provides specialized | |
| functions. Groups of these objects are used by software to provide | |
| Ethernet network interface functionality. This approach provides | |
| efficient use of finite hardware resources, flexibility, and | |
| performance advantages. | |
| The diagram below shows the objects needed for a simple | |
| network interface configuration on a system with 2 CPUs. | |
| :: | |
| +---+---+ +---+---+ | |
| CPU0 CPU1 | |
| +---+---+ +---+---+ | |
| | | | |
| +---+---+ +---+---+ | |
| DPIO DPIO | |
| +---+---+ +---+---+ | |
| \ / | |
| \ / | |
| \ / | |
| +---+---+ | |
| DPNI --- DPBP,DPMCP | |
| +---+---+ | |
| | | |
| | | |
| +---+---+ | |
| DPMAC | |
| +---+---+ | |
| | | |
| port/PHY | |
| Below the objects are described. For each object a brief description | |
| is provided along with a summary of the kinds of operations the object | |
| supports and a summary of key resources of the object (MMIO regions | |
| and IRQs). | |
| DPMAC (Datapath Ethernet MAC) | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| Represents an Ethernet MAC, a hardware device that connects to an Ethernet | |
| PHY and allows physical transmission and reception of Ethernet frames. | |
| - MMIO regions: none | |
| - IRQs: DPNI link change | |
| - commands: set link up/down, link config, get stats, | |
| IRQ config, enable, reset | |
| DPNI (Datapath Network Interface) | |
| Contains TX/RX queues, network interface configuration, and RX buffer pool | |
| configuration mechanisms. The TX/RX queues are in memory and are identified | |
| by queue number. | |
| - MMIO regions: none | |
| - IRQs: link state | |
| - commands: port config, offload config, queue config, | |
| parse/classify config, IRQ config, enable, reset | |
| DPIO (Datapath I/O) | |
| ~~~~~~~~~~~~~~~~~~~ | |
| Provides interfaces to enqueue and dequeue | |
| packets and do hardware buffer pool management operations. The DPAA2 | |
| architecture separates the mechanism to access queues (the DPIO object) | |
| from the queues themselves. The DPIO provides an MMIO interface to | |
| enqueue/dequeue packets. To enqueue something a descriptor is written | |
| to the DPIO MMIO region, which includes the target queue number. | |
| There will typically be one DPIO assigned to each CPU. This allows all | |
| CPUs to simultaneously perform enqueue/dequeued operations. DPIOs are | |
| expected to be shared by different DPAA2 drivers. | |
| - MMIO regions: queue operations, buffer management | |
| - IRQs: data availability, congestion notification, buffer | |
| pool depletion | |
| - commands: IRQ config, enable, reset | |
| DPBP (Datapath Buffer Pool) | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| Represents a hardware buffer pool. | |
| - MMIO regions: none | |
| - IRQs: none | |
| - commands: enable, reset | |
| DPMCP (Datapath MC Portal) | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| Provides an MC command portal. | |
| Used by drivers to send commands to the MC to manage | |
| objects. | |
| - MMIO regions: MC command portal | |
| - IRQs: command completion | |
| - commands: IRQ config, enable, reset | |
| Object Connections | |
| ================== | |
| Some objects have explicit relationships that must | |
| be configured: | |
| - DPNI <--> DPMAC | |
| - DPNI <--> DPNI | |
| - DPNI <--> L2-switch-port | |
| A DPNI must be connected to something such as a DPMAC, | |
| another DPNI, or L2 switch port. The DPNI connection | |
| is made via a DPRC command. | |
| :: | |
| +-------+ +-------+ | |
| | DPNI | | DPMAC | | |
| +---+---+ +---+---+ | |
| | | | |
| +==========+ | |
| - DPNI <--> DPBP | |
| A network interface requires a 'buffer pool' (DPBP | |
| object) which provides a list of pointers to memory | |
| where received Ethernet data is to be copied. The | |
| Ethernet driver configures the DPBPs associated with | |
| the network interface. | |
| Interrupts | |
| ========== | |
| All interrupts generated by DPAA2 objects are message | |
| interrupts. At the hardware level message interrupts | |
| generated by devices will normally have 3 components-- | |
| 1) a non-spoofable 'device-id' expressed on the hardware | |
| bus, 2) an address, 3) a data value. | |
| In the case of DPAA2 devices/objects, all objects in the | |
| same container/DPRC share the same 'device-id'. | |
| For ARM-based SoC this is the same as the stream ID. | |
| DPAA2 Linux Drivers Overview | |
| ============================ | |
| This section provides an overview of the Linux kernel drivers for | |
| DPAA2-- 1) the bus driver and associated "DPAA2 infrastructure" | |
| drivers and 2) functional object drivers (such as Ethernet). | |
| As described previously, a DPRC is a container that holds the other | |
| types of DPAA2 objects. It is functionally similar to a plug-and-play | |
| bus controller. | |
| Each object in the DPRC is a Linux "device" and is bound to a driver. | |
| The diagram below shows the Linux drivers involved in a networking | |
| scenario and the objects bound to each driver. A brief description | |
| of each driver follows. | |
| :: | |
| +------------+ | |
| | OS Network | | |
| | Stack | | |
| +------------+ +------------+ | |
| | Allocator |. . . . . . . | Ethernet | | |
| |(DPMCP,DPBP)| | (DPNI) | | |
| +-.----------+ +---+---+----+ | |
| . . ^ | | |
| . . <data avail, | | <enqueue, | |
| . . tx confirm> | | dequeue> | |
| +-------------+ . | | | |
| | DPRC driver | . +---+---V----+ +---------+ | |
| | (DPRC) | . . . . . .| DPIO driver| | MAC | | |
| +----------+--+ | (DPIO) | | (DPMAC) | | |
| | +------+-----+ +-----+---+ | |
| |<dev add/remove> | | | |
| | | | | |
| +--------+----------+ | +--+---+ | |
| | MC-bus driver | | | PHY | | |
| | | | |driver| | |
| | /bus/fsl-mc | | +--+---+ | |
| +-------------------+ | | | |
| | | | |
| ========================= HARDWARE =========|=================|====== | |
| DPIO | | |
| | | | |
| DPNI---DPBP | | |
| | | | |
| DPMAC | | |
| | | | |
| PHY ---------------+ | |
| ============================================|======================== | |
| A brief description of each driver is provided below. | |
| MC-bus driver | |
| ------------- | |
| The MC-bus driver is a platform driver and is probed from a | |
| node in the device tree (compatible "fsl,qoriq-mc") passed in by boot | |
| firmware. It is responsible for bootstrapping the DPAA2 kernel | |
| infrastructure. | |
| Key functions include: | |
| - registering a new bus type named "fsl-mc" with the kernel, | |
| and implementing bus call-backs (e.g. match/uevent/dev_groups) | |
| - implementing APIs for DPAA2 driver registration and for device | |
| add/remove | |
| - creates an MSI IRQ domain | |
| - doing a 'device add' to expose the 'root' DPRC, in turn triggering | |
| a bind of the root DPRC to the DPRC driver | |
| The binding for the MC-bus device-tree node can be consulted at | |
| *Documentation/devicetree/bindings/misc/fsl,qoriq-mc.txt*. | |
| The sysfs bind/unbind interfaces for the MC-bus can be consulted at | |
| *Documentation/ABI/testing/sysfs-bus-fsl-mc*. | |
| DPRC driver | |
| ----------- | |
| The DPRC driver is bound to DPRC objects and does runtime management | |
| of a bus instance. It performs the initial bus scan of the DPRC | |
| and handles interrupts for container events such as hot plug by | |
| re-scanning the DPRC. | |
| Allocator | |
| --------- | |
| Certain objects such as DPMCP and DPBP are generic and fungible, | |
| and are intended to be used by other drivers. For example, | |
| the DPAA2 Ethernet driver needs: | |
| - DPMCPs to send MC commands, to configure network interfaces | |
| - DPBPs for network buffer pools | |
| The allocator driver registers for these allocatable object types | |
| and those objects are bound to the allocator when the bus is probed. | |
| The allocator maintains a pool of objects that are available for | |
| allocation by other DPAA2 drivers. | |
| DPIO driver | |
| ----------- | |
| The DPIO driver is bound to DPIO objects and provides services that allow | |
| other drivers such as the Ethernet driver to enqueue and dequeue data for | |
| their respective objects. | |
| Key services include: | |
| - data availability notifications | |
| - hardware queuing operations (enqueue and dequeue of data) | |
| - hardware buffer pool management | |
| To transmit a packet the Ethernet driver puts data on a queue and | |
| invokes a DPIO API. For receive, the Ethernet driver registers | |
| a data availability notification callback. To dequeue a packet | |
| a DPIO API is used. | |
| There is typically one DPIO object per physical CPU for optimum | |
| performance, allowing different CPUs to simultaneously enqueue | |
| and dequeue data. | |
| The DPIO driver operates on behalf of all DPAA2 drivers | |
| active in the kernel-- Ethernet, crypto, compression, | |
| etc. | |
| Ethernet driver | |
| --------------- | |
| The Ethernet driver is bound to a DPNI and implements the kernel | |
| interfaces needed to connect the DPAA2 network interface to | |
| the network stack. | |
| Each DPNI corresponds to a Linux network interface. | |
| MAC driver | |
| ---------- | |
| An Ethernet PHY is an off-chip, board specific component and is managed | |
| by the appropriate PHY driver via an mdio bus. The MAC driver | |
| plays a role of being a proxy between the PHY driver and the | |
| MC. It does this proxy via the MC commands to a DPMAC object. | |
| If the PHY driver signals a link change, the MAC driver notifies | |
| the MC via a DPMAC command. If a network interface is brought | |
| up or down, the MC notifies the DPMAC driver via an interrupt and | |
| the driver can take appropriate action. |