|  | PLIP: The Parallel Line Internet Protocol Device | 
|  |  | 
|  | Donald Becker (becker@super.org) | 
|  | I.D.A. Supercomputing Research Center, Bowie MD 20715 | 
|  |  | 
|  | At some point T. Thorn will probably contribute text, | 
|  | Tommy Thorn (tthorn@daimi.aau.dk) | 
|  |  | 
|  | PLIP Introduction | 
|  | ----------------- | 
|  |  | 
|  | This document describes the parallel port packet pusher for Net/LGX. | 
|  | This device interface allows a point-to-point connection between two | 
|  | parallel ports to appear as a IP network interface. | 
|  |  | 
|  | What is PLIP? | 
|  | ============= | 
|  |  | 
|  | PLIP is Parallel Line IP, that is, the transportation of IP packages | 
|  | over a parallel port. In the case of a PC, the obvious choice is the | 
|  | printer port.  PLIP is a non-standard, but [can use] uses the standard | 
|  | LapLink null-printer cable [can also work in turbo mode, with a PLIP | 
|  | cable]. [The protocol used to pack IP packages, is a simple one | 
|  | initiated by Crynwr.] | 
|  |  | 
|  | Advantages of PLIP | 
|  | ================== | 
|  |  | 
|  | It's cheap, it's available everywhere, and it's easy. | 
|  |  | 
|  | The PLIP cable is all that's needed to connect two Linux boxes, and it | 
|  | can be built for very few bucks. | 
|  |  | 
|  | Connecting two Linux boxes takes only a second's decision and a few | 
|  | minutes' work, no need to search for a [supported] netcard. This might | 
|  | even be especially important in the case of notebooks, where netcards | 
|  | are not easily available. | 
|  |  | 
|  | Not requiring a netcard also means that apart from connecting the | 
|  | cables, everything else is software configuration [which in principle | 
|  | could be made very easy.] | 
|  |  | 
|  | Disadvantages of PLIP | 
|  | ===================== | 
|  |  | 
|  | Doesn't work over a modem, like SLIP and PPP. Limited range, 15 m. | 
|  | Can only be used to connect three (?) Linux boxes. Doesn't connect to | 
|  | an existing Ethernet. Isn't standard (not even de facto standard, like | 
|  | SLIP). | 
|  |  | 
|  | Performance | 
|  | =========== | 
|  |  | 
|  | PLIP easily outperforms Ethernet cards....(ups, I was dreaming, but | 
|  | it *is* getting late. EOB) | 
|  |  | 
|  | PLIP driver details | 
|  | ------------------- | 
|  |  | 
|  | The Linux PLIP driver is an implementation of the original Crynwr protocol, | 
|  | that uses the parallel port subsystem of the kernel in order to properly | 
|  | share parallel ports between PLIP and other services. | 
|  |  | 
|  | IRQs and trigger timeouts | 
|  | ========================= | 
|  |  | 
|  | When a parallel port used for a PLIP driver has an IRQ configured to it, the | 
|  | PLIP driver is signaled whenever data is sent to it via the cable, such that | 
|  | when no data is available, the driver isn't being used. | 
|  |  | 
|  | However, on some machines it is hard, if not impossible, to configure an IRQ | 
|  | to a certain parallel port, mainly because it is used by some other device. | 
|  | On these machines, the PLIP driver can be used in IRQ-less mode, where | 
|  | the PLIP driver would constantly poll the parallel port for data waiting, | 
|  | and if such data is available, process it. This mode is less efficient than | 
|  | the IRQ mode, because the driver has to check the parallel port many times | 
|  | per second, even when no data at all is sent. Some rough measurements | 
|  | indicate that there isn't a noticeable performance drop when using IRQ-less | 
|  | mode as compared to IRQ mode as far as the data transfer speed is involved. | 
|  | There is a performance drop on the machine hosting the driver. | 
|  |  | 
|  | When the PLIP driver is used in IRQ mode, the timeout used for triggering a | 
|  | data transfer (the maximal time the PLIP driver would allow the other side | 
|  | before announcing a timeout, when trying to handshake a transfer of some | 
|  | data) is, by default, 500usec. As IRQ delivery is more or less immediate, | 
|  | this timeout is quite sufficient. | 
|  |  | 
|  | When in IRQ-less mode, the PLIP driver polls the parallel port HZ times | 
|  | per second (where HZ is typically 100 on most platforms, and 1024 on an | 
|  | Alpha, as of this writing). Between two such polls, there are 10^6/HZ usecs. | 
|  | On an i386, for example, 10^6/100 = 10000usec. It is easy to see that it is | 
|  | quite possible for the trigger timeout to expire between two such polls, as | 
|  | the timeout is only 500usec long. As a result, it is required to change the | 
|  | trigger timeout on the *other* side of a PLIP connection, to about | 
|  | 10^6/HZ usecs. If both sides of a PLIP connection are used in IRQ-less mode, | 
|  | this timeout is required on both sides. | 
|  |  | 
|  | It appears that in practice, the trigger timeout can be shorter than in the | 
|  | above calculation. It isn't an important issue, unless the wire is faulty, | 
|  | in which case a long timeout would stall the machine when, for whatever | 
|  | reason, bits are dropped. | 
|  |  | 
|  | A utility that can perform this change in Linux is plipconfig, which is part | 
|  | of the net-tools package (its location can be found in the | 
|  | Documentation/Changes file). An example command would be | 
|  | 'plipconfig plipX trigger 10000', where plipX is the appropriate | 
|  | PLIP device. | 
|  |  | 
|  | PLIP hardware interconnection | 
|  | ----------------------------- | 
|  |  | 
|  | PLIP uses several different data transfer methods.  The first (and the | 
|  | only one implemented in the early version of the code) uses a standard | 
|  | printer "null" cable to transfer data four bits at a time using | 
|  | data bit outputs connected to status bit inputs. | 
|  |  | 
|  | The second data transfer method relies on both machines having | 
|  | bi-directional parallel ports, rather than output-only ``printer'' | 
|  | ports.  This allows byte-wide transfers and avoids reconstructing | 
|  | nibbles into bytes, leading to much faster transfers. | 
|  |  | 
|  | Parallel Transfer Mode 0 Cable | 
|  | ============================== | 
|  |  | 
|  | The cable for the first transfer mode is a standard | 
|  | printer "null" cable which transfers data four bits at a time using | 
|  | data bit outputs of the first port (machine T) connected to the | 
|  | status bit inputs of the second port (machine R).  There are five | 
|  | status inputs, and they are used as four data inputs and a clock (data | 
|  | strobe) input, arranged so that the data input bits appear as contiguous | 
|  | bits with standard status register implementation. | 
|  |  | 
|  | A cable that implements this protocol is available commercially as a | 
|  | "Null Printer" or "Turbo Laplink" cable.  It can be constructed with | 
|  | two DB-25 male connectors symmetrically connected as follows: | 
|  |  | 
|  | STROBE output	1* | 
|  | D0->ERROR	2 - 15		15 - 2 | 
|  | D1->SLCT	3 - 13		13 - 3 | 
|  | D2->PAPOUT	4 - 12		12 - 4 | 
|  | D3->ACK	5 - 10		10 - 5 | 
|  | D4->BUSY	6 - 11		11 - 6 | 
|  | D5,D6,D7 are   7*, 8*, 9* | 
|  | AUTOFD output 14* | 
|  | INIT   output 16* | 
|  | SLCTIN	17 - 17 | 
|  | extra grounds are 18*,19*,20*,21*,22*,23*,24* | 
|  | GROUND	25 - 25 | 
|  | * Do not connect these pins on either end | 
|  |  | 
|  | If the cable you are using has a metallic shield it should be | 
|  | connected to the metallic DB-25 shell at one end only. | 
|  |  | 
|  | Parallel Transfer Mode 1 | 
|  | ======================== | 
|  |  | 
|  | The second data transfer method relies on both machines having | 
|  | bi-directional parallel ports, rather than output-only ``printer'' | 
|  | ports.  This allows byte-wide transfers, and avoids reconstructing | 
|  | nibbles into bytes.  This cable should not be used on unidirectional | 
|  | ``printer'' (as opposed to ``parallel'') ports or when the machine | 
|  | isn't configured for PLIP, as it will result in output driver | 
|  | conflicts and the (unlikely) possibility of damage. | 
|  |  | 
|  | The cable for this transfer mode should be constructed as follows: | 
|  |  | 
|  | STROBE->BUSY 1 - 11 | 
|  | D0->D0	2 - 2 | 
|  | D1->D1	3 - 3 | 
|  | D2->D2	4 - 4 | 
|  | D3->D3	5 - 5 | 
|  | D4->D4	6 - 6 | 
|  | D5->D5	7 - 7 | 
|  | D6->D6	8 - 8 | 
|  | D7->D7	9 - 9 | 
|  | INIT -> ACK  16 - 10 | 
|  | AUTOFD->PAPOUT 14 - 12 | 
|  | SLCT->SLCTIN 13 - 17 | 
|  | GND->ERROR	18 - 15 | 
|  | extra grounds are 19*,20*,21*,22*,23*,24* | 
|  | GROUND	25 - 25 | 
|  | * Do not connect these pins on either end | 
|  |  | 
|  | Once again, if the cable you are using has a metallic shield it should | 
|  | be connected to the metallic DB-25 shell at one end only. | 
|  |  | 
|  | PLIP Mode 0 transfer protocol | 
|  | ============================= | 
|  |  | 
|  | The PLIP driver is compatible with the "Crynwr" parallel port transfer | 
|  | standard in Mode 0.  That standard specifies the following protocol: | 
|  |  | 
|  | send header nibble '0x8' | 
|  | count-low octet | 
|  | count-high octet | 
|  | ... data octets | 
|  | checksum octet | 
|  |  | 
|  | Each octet is sent as | 
|  | <wait for rx. '0x1?'>	<send 0x10+(octet&0x0F)> | 
|  | <wait for rx. '0x0?'>	<send 0x00+((octet>>4)&0x0F)> | 
|  |  | 
|  | To start a transfer the transmitting machine outputs a nibble 0x08. | 
|  | That raises the ACK line, triggering an interrupt in the receiving | 
|  | machine.  The receiving machine disables interrupts and raises its own ACK | 
|  | line. | 
|  |  | 
|  | Restated: | 
|  |  | 
|  | (OUT is bit 0-4, OUT.j is bit j from OUT. IN likewise) | 
|  | Send_Byte: | 
|  | OUT := low nibble, OUT.4 := 1 | 
|  | WAIT FOR IN.4 = 1 | 
|  | OUT := high nibble, OUT.4 := 0 | 
|  | WAIT FOR IN.4 = 0 |