spi/pl022: fix erroneous platform data in U300

This fixes an erroneous use of LSB first in the U300 machine, the
PL022 used in U300 is a standard ARM core that doesn't support this
bit so it should never have been set.

Cc: Kevin Wells <wellsk40@gmail.com>OA
Signed-off-by: Linus Walleij <linus.walleij@stericsson.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
diff --git a/arch/arm/mach-u300/spi.c b/arch/arm/mach-u300/spi.c
index edb2c0d..00869de 100644
--- a/arch/arm/mach-u300/spi.c
+++ b/arch/arm/mach-u300/spi.c
@@ -67,7 +67,7 @@
 		.bus_num        = 0, /* Only one bus on this chip */
 		.chip_select    = 0,
 		/* Means SPI_CS_HIGH, change if e.g low CS */
-		.mode           = SPI_MODE_1 | SPI_LSB_FIRST | SPI_LOOP,
+		.mode           = SPI_MODE_1 | SPI_LOOP,
 	},
 #endif
 };